Balaji Technomed
Balaji Technomed
  • Home
  • About Us
  • Our Products
    • AUTO REF. HANDHELD
    • ADULT FUNDUS CAMERA
    • NEONATAL RETINAL CAMERA
    • SENSORTEK (USA) LENSES
    • OPTICAL BIOMETER
    • MICROSURGICAL KNIVES
  • Contact Us
  • More
    • Home
    • About Us
    • Our Products
      • AUTO REF. HANDHELD
      • ADULT FUNDUS CAMERA
      • NEONATAL RETINAL CAMERA
      • SENSORTEK (USA) LENSES
      • OPTICAL BIOMETER
      • MICROSURGICAL KNIVES
    • Contact Us

  • Home
  • About Us
  • Our Products
    • AUTO REF. HANDHELD
    • ADULT FUNDUS CAMERA
    • NEONATAL RETINAL CAMERA
    • SENSORTEK (USA) LENSES
    • OPTICAL BIOMETER
    • MICROSURGICAL KNIVES
  • Contact Us

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

Next-Generation Optical Biometer for Myopia Monitoring with Comprehensive Myopia Management Report

3nethra bio, Optical Biometer

Advanced ophthalmic imaging device for eye health diagnostics.

Technical Specifications

Additional Feature: Comprehensive Myopia Management Report Available

Additional Feature: Comprehensive Myopia Management Report Available

Additional Feature: Comprehensive Myopia Management Report Available

Additional Feature: Comprehensive Myopia Management Report Available

Additional Feature: Comprehensive Myopia Management Report Available

Additional Feature: Comprehensive Myopia Management Report Available

Next-Generation Optical Biometer with Myopia Monitoring & Ocular Biometry

3nethra bio — Precise Ocular Biometry • Myopia Monitoring • Myopia Management Report

3nethra bio is a next-generation optical biometer engineered for accurate Ocular Biometry and clinical Myopia Monitoring. Using low-coherence interferometry (OLCR) the system provides fast, non-contact measurements of axial length and other essential ocular parameters and generates a structured Myopia Management Report for long-term patient tracking and clinical decision support.


Why choose 3nethra bio?

  • Dedicated to Myopia Care: Built for reliable axial length tracking and longitudinal data, powering evidence-based Myopia Monitoring programs.
  • Comprehensive Ocular Biometry: Measures axial length (AL), central corneal thickness (CCT), corneal curvature (K1/K2), anterior chamber depth (ACD), lens thickness (LT), white-to-white (WTW) and pupil diameter, all essential for cataract, refractive and myopia workflows.
  • Multi-formula IOL Calculation: Supports standard formulas (SRK-II, SRK/T, Hoffer-Q, Holladay 1, Haigis) for precise intraocular lens planning.
  • Fast & Repeatable: Monocular measurements in seconds and binocular detection in under 20 seconds, improving throughput while maintaining high repeatability.


Key Features

  • Optical Low Coherence Reflectometry (OLCR): Sub-micron axial accuracy for consistent, reliable measurements. 
  • 32-Point Corneal Analysis: Concentric light-point projection for precise corneal curvature and repeatable keratometry.
  • Dual Modes: Standard mode for aphakic eyes and Pro mode for phakic/pseudophakic eyes for broader clinical applicability.
  • 10-inch Touchscreen: Intuitive interface with guided alignment for simple operation in busy clinics.
  • Smart Reporting & Cloud Integration: Automatic PDF report generation and secure cloud storage (Forus Cloud) for easy retrieval and record keeping.


Clinical Benefits

  • Improve Myopia Care: Generate a Myopia Management Report that includes baseline axial length, progression trends and visualizable charts to communicate risk and monitor interventions with patients and parents.
  • Reduce Refractive Surprises: Accurate ocular biometry and multi-formula IOL calculations help optimize refractive outcomes after cataract surgery.
  • Streamline Workflow: Quick acquisitions and automated reporting reduce chair time while improving documentation quality.
  • Patient Comfort & Safety: Non-contact optical measurement minimizes patient discomfort compared with contact ultrasound methods.


Technical Specifications (Summary)

ParameterRange / DetailAxial Length (AL): 12 – 38 mm.

Corneal Curvature (K1 & K2): 4.7 – 11.5 mm.

Central Corneal Thickness (CCT): 300 – 800 µm.

Anterior Chamber Depth (ACD): 1.5 – 6.5 mm.

Lens Thickness (LT): 0.5 – 7.0 mm.

White-to-White (WTW): 6 – 17 mm.

Pupil Diameter: 1.8 – 13.6 mm.

Display: 10-inch touchscreen.

Size & Weight: 410 × 240 × 410 mm; ~15 kg. 


Typical Use Cases

  • Pediatric & Adult Myopia Monitoring: Track axial growth and generate periodic Myopia Management Reports to guide interventions. 
  • Cataract & Refractive Planning: Accurate ocular biometry and IOL calculations for routine and premium cataract cases.
  • Multi-site Clinics & Camps: Compact and portable design supports satellite clinics and outreach programs.


What’s included / Integration

  • Device with touchscreen console, measurement software, and reporting tools.
  • PDF report generation and Forus Cloud compatibility for secure storage and remote access of reports.


Call to action

Want a demo or quotation ? Contact Balaji Technomed

Contact us today for a live demo, on-site evaluation, or to request clinical brochures and sample Myopia Management Reports.

Contact Us
  • Privacy Policy
  • Terms and Conditions
  • BLOGS

Copyright © 2017 Balaji Technomed - All Rights Reserved.

**Product may vary from images on the website.

THIS WEBSITE USES COOKIES.

 “We use cookies to improve your browsing experience and analyze website traffic. By accepting, your browsing data will be combined with other users’ data to help us optimize our website.” 

Accept

Exclusive Introductory Deal

3NETHRA BIO - Optical Biometer

👇 Additional Feature 👇

COMPREHENSIVE MYOPIA MANAGEMENT REPORT AVAILABLE

Send your query for more information.

Learn More... & Contact Us ➺