3nethra bio, Optical Biometer

3nethra bio
optical biometer
oclr technology

ABOUT OPTICAL BIOMETER

An optical biometer is a medical device used in ophthalmology to measure the anatomical characteristics of the eye using non-contact optical methods, most commonly optical coherence interferometry or optical low-coherence reflectometry.


Primary Purpose

Optical biometers are primarily used to calculate intraocular lens (IOL) power before cataract surgery or refractive lens exchange, ensuring the patient achieves the desired postoperative visual outcome.


Key Parameters Measured

  1. Axial Length (AL) – The length of the eye from the front (cornea) to the retina. Crucial for IOL power calculation 
  2. Keratometry (K1, K2) – Curvature of the cornea’s front surface, used to assess corneal power.
  3. Anterior Chamber Depth (ACD) – Distance from the corneal endothelium to the lens.
  4. Lens Thickness (LT) – Thickness of the natural lens.
  5. White-to-White (WTW) – Horizontal corneal diameter.
  6. Central Corneal Thickness (CCT) – Useful in some biometric formulas and for other diagnostics.
     

Technologies Used

  • Partial coherence interferometry (PCI)
  • Optical low-coherence reflectometry (OLCR).
  • Swept-source OCT (SS-OCT)
     

Applications

  • Pre-surgical planning for:
    • Cataract surgery
    • Refractive lens exchange
    • Pediatric lens implantation
  • Myopia management and axial length monitoring
  • Post-refractive surgery IOL calculations (with appropriate formulas)
     

Advantages Over Ultrasound Biometry

  • Non-contact: More comfortable and lower risk of infection 
  • Higher accuracy: Especially in axial length
  • Faster and easier: Particularly for bilateral measurements.
     

3NETHRA BIO:

Refined Description (Professional/Marketing Tone):

3nethra Bio is an advanced optical biometer that employs low-coherence interferometry to deliver high-precision measurements of essential ocular parameters. Designed for accuracy and efficiency, it ensures precise alignment with the eye's optical axis, capturing key metrics such as:

  • Axial Length (AL 
  • Central Corneal Thickness (CCT)
  • Corneal Curvature (K-values)
  • Anterior Chamber Depth (ACD)
  • Lens Thickness (LT)
  • White-to-White (WTW) Distance
  • Pupil Diameter
     

The device also calculates intraocular lens (IOL) power to support optimal refractive outcomes in cataract and lens replacement surgeries. Its intuitive interface and streamlined workflow improve diagnostic accuracy, facilitate confident treatment planning, and boost overall clinical productivity.


Customization Options:

1. For Website (Short-form Version):

The 3nethra Bio is a cutting-edge optical biometer using low-coherence interferometry to measure axial length, corneal thickness and curvature, ACD, lens thickness, and more. It ensures precise IOL power calculations and enhances surgical planning with an intuitive, clinician-friendly interface. 

2. For Technical Brochure (Bullet-style):

  • Optical biometer with low-coherence interferometry
  • Accurate alignment with the eye's visual axis
  • Measures:
    • Axial length (AL)
    • Central corneal thickness (CCT)
    • Corneal curvature (K1, K2)
    • Anterior chamber depth (ACD)
    • Lens thickness (LT)
    • White-to-white (WTW)
    • Pupil diameter
  • IOL power calculation with advanced formulas
  • Intuitive interface for streamlined workflow
  • Enhances diagnostic precision and surgical outcomes
     

3. For Clinician Training Material:

With the 3nethra Bio, clinicians can rely on repeatable, high-resolution ocular biometry for preoperative planning. The system’s guided alignment and robust measurement suite support confident IOL selection and efficient patient workflow.

Clinical Highlights

High-Precision Axial Measurements with OLCR Technology

Utilizes Optical Low Coherence Reflectometry (OLCR) to deliver sub-micron axial measurement accuracy, effectively minimizing refractive index-related errors for superior biometry performance.

Advanced Corneal Analysis with 32 Light Points

Projects 32 concentric light points onto the cornea to ensure highly accurate and repeatable curvature measurements, supporting reliable preoperative assessments.


Comprehensive Insights into Myopia, Cataracts, and Visual Quality

Provides advanced analysis of:

  • Axial growth trends for myopia management
  • Cataract grading and surgical planning
  • Strabismus screening and Kappa angle evaluation
  • Assessment of visual quality metrics
     

Multi-Formula IOL Power Calculation

Supports a wide range of IOL calculation formulas for personalized and precise outcomes: SRK/T, SRK II, Hoffer-Q, Hoffer-Colenbrander, Holladay 1, Haigis, Haigis-L, Binkhorst, Shammas.
 

10-Inch Touchscreen Interface

A large, high-resolution touchscreen enables intuitive, efficient operation, streamlining the workflow in busy clinical environments.


Forus Cloud Integration*

Automatically generates and uploads PDF reports, with secure cloud storage for:

  • Seamless data access
  • Centralized documentation
  • Easy patient record management
     

Compact and Lightweight Design

Engineered for flexibility and portability, making it ideal for diverse clinical setups, including outpatient departments, satellite clinics, and mobile eye care units.

ADVANTAGES & SPECIFICATIONS

Advantages of 3nethra bio

  • Rapid Measurement: Performs monocular measurements in mere seconds and completes binocular detections in under 20 seconds—significantly boosting clinical efficiency.


  • High Accuracy and Repeatability: Uses 32 concentric light points to deliver highly precise, consistent measurements across repeated assessments.


  • Comprehensive Diagnostic Capabilities: Enables advanced management and monitoring of various ocular conditions, including predicting refractive errors, tracking axial length growth, and facilitating evaluations for myopia, cataracts, corneal reshaping, and overall visual quality.


  • Kappa Angle Measurement Support: Measures the angular difference between the visual and optical axes, a crucial parameter for optimizing outcomes in cataract surgeries.


  • User-Friendly Operation: Features animated voice guidance for an intuitive and hassle-free user experience—especially helpful in busy clinical workflows.


  • Dual Mode Functionality Offers:
    • Standard Mode for aphakic eyes (eyes without a natural lens)
    • Pro Mode for phakic (natural lens present) and pseudophakic (with implanted IOL) eyes This adaptability ensures accurate measurements across different patient types.


Summary Table

Advantage Category Highlights

Speed Monocular: seconds; Binocular: under 20 seconds

Precision & Repeatability 32-point corneal projection system ensures consistency

Diagnostic Scope Supports myopia, cataract, visual quality assessments cross-functionally

Specialized Metrics Includes Kappa angle measurement for surgical precision

Ease-of-Use Animated voice-guided operation

Versatile Patient Modes Standard and Pro modes for different lens statuses 


System Specifications

Technology: Optical Low Coherence Reflectometry (OLCR)

Display: 10-inch Touchscreen Interface

Printer: External thermal printer + wireless connection for A4 printing

Connectivity: USB, HDMI, WiFi, Bluetooth

Power Supply: 100–240V AC, 50/60Hz → Output: 24V DC, 2.7A

Dimensions: 410 mm (L) × 240 mm (B) × 410 mm (H)

Weight: 15 kg  